Administrator's Guide

ResolutionRoot cause
Type/
SeverityDescription
Error
Code
directory or permissions are not
configured properly on this file.
remove the current firmware
bundle.
2. Install the HP_CMP_FW MSI file,
which is located in the
The Repository.xml file is
corrupted.
Error/
Critical
Error processing
Repository.xml -
0X1A03
C:\hpnas\Components\CMP
directory.
please check that this file
is well-formed XML
One or more Smart Components
(SC) is missing from the
Error/
Critical
Smart Component file
described in repository
0X1A04
C:\ProgramData\Hewlett-does not exist or is not
readable: %s
Packard\CMP\Firmware
directory.
The Version tag of the
Repository.xml file is not
Error/
Critical
Error processing
Repository file %s: version
not compatible
0X1A0D
compatible. This occurs when the
Repository.xml file is
corrupted.
These error message may display
if there is a problem creating or
Error/
Critical
Smart Component
discovery failed for %s
0X1A05 1. Check the logs for more
information.
reading a temporaryusing %s: unable to create
temp directory %s
2. Free up space or set the correct
permissions on the temporary
directory mentioned in the error
message.
file/directory that is used for the
discovery/flash operation for
some Smart Components.
Error/
Critical
Smart Component
discovery failed for %s
0X1A06
3. Retry the discovery/flash
operation.
using %s: error reading
the discovery file: %s.
Check the log (%s in %s)
for more information
Error/
Critical
Smart Component
discovery failed for %s
0X1A0F
using %s: discovery file
not created: %s. Check
log file %s for more
information
Error/
Critical
Flash not attempted for %s
using %s: unable to create
temporary directory %s.
0x1027
Check the logs for more
information and proceed
accordingly.
An internal error occurred during
the discovery/flash operation,
due to Smart Component
Error/
Critical
Internal CMP error - see
the log file (%s in %s) for
more information.
0X1A07
execution failures or an
Error/
Critical
Internal CMP error - see
log file (%s) for more
information
0X1A08
unexpected response from the
Smart Components. Also, the tool
might have encountered an error
condition that aborted the
operation.
Error/
Critical
Flash not attempted using
%s: Internal CMP error -
0x1020
see log file (%s) for more
information.
Error/
Critical
Smart Component
discovery failed for %s
0x1A10
using %s: invalid response
from Smart Component.
Check the log file (%s in
%s) for more information
An error occurred while
discovering the active firmware
version.
Error/
Critical
Error inspecting firmware
for %s: Internal CMP error
- see log file (%s in %s) for
more information.
0X1A0B
CMP 173