Administrator's Guide
ResolutionDescriptionError
Code
Program Files (x86)\Hewlett-Packard\E5000\HP
Firmware Update Tool\ .
See the error message for details. The UpgradeSelected.xml
file must be opened and read for a firmware upgrade to occur.
(W) Error opening file
UpgradeSelected.xml.
2049
Open the file in Internet Explorer or a similar browser to check
the format. This will also validate that the file exists and can be
opened. Otherwise, delete the file, which is located in C:\
Program Files (x86)\Hewlett-Packard\E5000\HP
Firmware Update Tool\.
See the error message for details. This list must be cleared so
that duplicate entries are not displayed after a discovery. No
action required.
(I)Error clearing components from the list of
components needing upgrade.
2050
See the error message for details. There was a problem
processing data returned during the discovery operation. Apply
Error processing discovery information from
CMP service
2051
the suggestion displayed in the E5000 System Manager to
resolve the issue.
See the error message for details. There was a problem
communicating with CMP to start the discovery operation.
Error communicating with CMP service to get
discovery information
2052
Validate that the HP CMP service is started. Using the Control
Panel, verify that the HP CMP Firmware is installed.
The HP CMP service encountered an error. Troubleshoot the
CMP error. Details can be found in the file C:\ProgramData\
Hewlett-Packard\logs\hpFWUpdateTool_log.txt.
(I) Error response from HP CMP service while
getting discovery information
2053
See the error message for details. There was a problem
processing data returned during a firmware upgrade. Apply
Error processing data returned from the
firmware upgrade operation
2054
the suggestion displayed in the E5000 System Manager to
resolve.
See the error message for details. There was a problem
communicating with CMP to start the upgrade. Validate that
Error communicating with CMP during an
upgrade operation
2055
the HP CMP service is started. Using the Control Panel, verify
that the HP CMP Firmware is installed.
The CMP service encountered an error. View the CMP error
details in the file C:\ProgramData\Hewlett-Packard\
Error response from CMP during an upgrade
operation
2056
logs\hpFWUpdateTool_log.txt. The component’s
firmware may not have been upgraded.
See the error message for details. There was a problem sending
data to CMP during an upgrade. Apply the suggestion displayed
in the E5000 System Manager to resolve.
Error sending data to CMP Service during
firmware upgrade.
2057
See the error message for details. There was a problem
communicating with CMP to start the upgrade. Verify that the
Web Error on POST Request in
upgradeComponent.
2058
HP CMP service is started. Using the Control Panel, verify that
the HP CMP Firmware is installed.
Reserved for future use.(I) Error in RespCallBack.2059
Reserved for future use.(I) Web Error in RespCallBack.2060
Reserved for future use.(I) Error in ReadCallBack.2061
Reserved for future use.(I) Web Error in ReadCallBack.2062
Reserved for future use.(I) Error in SearchAllDevices.2063
See the error message for details. There was a problem
processing data returned during the discovery operation. Apply
Error received in response to Upgrade request
in upgradeComponent.
2064
the suggestion displayed in the E5000 System Manager to
resolve the issue.
Firmware Update 169