Administrator's Guide
4. Release the UP button.
The system sets the EM to Link local mode and exits the menu mode. This event is also logged
in the EM syslog and takes effect immediately. The system displays the Enclosure ID to indicate
that the operation is complete.
Display Current IP Address (IP)
Learn the IP address of the EM.
To find the current IP address:
1. Enter the menu mode using the “Activate Button Menu” (page 161).
2. Press the UP button until the display changes from “_ _“ to “IP”.
3. Press and hold the UP button for three seconds.
The EM displays “IP” to acknowledge the selection.
4. Release the UP button.
The system enters the ‘Display IP’ subfunction and displays the first octet of the IPv4 address
being used by the EM.
5. Press the UP button three times to scroll through the other three octets of the EM IP address.
You can back up using the DOWN button.
6. Press and hold the DOWN button for three seconds.
The EM flashes “IP” to acknowledge the selection, and then exits the operation. The system
displays the Enclosure ID to indicate that the operation is complete.
Exit Button Menu
Exit the main menu (or any subfunction).
To exit the button menu:
Press and hold the DOWN button for three seconds.
The system displays and flashes the two hyphens (“- -“) three times to indicate the menu was exited.
The system then returns the LEDs to the original display state showing the Enclosure ID.
Display Current IP Address (IP) 163