Administrator's Guide
NOTE: Because the EMU hardware cannot determine if a blade is physically present unless
enclosure power is on, the EM reports the warning that the blade is not present if this command
is used when enclosure power is off.
SET SERVER BOOT
Syntax
SET SERVER BOOT { FIRST | ONCE } { NORMAL | HDD | PXE | RBSU } { ALL |
<bay#> [{ , | - } <bay#>]}
Description
Persistently stores a setting for the IPL to be passed to the specified servers at the next reboot.
SET SERVER BOOT FIRST sets the boot order of the blade.
SET SERVER BOOT ONCE sets the boot device to be used on the next boot of the specified bay;
The RBSU option is only available for SET SERVER BOOT ONCE.
Restrictions
• This setting is only valid on present blades and is cleared if the blade is removed.
• This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports
the warning that the blade is not present if this command is used when enclosure power is
off.
SHOW SERVER BOOT
Syntax
SHOW SERVER BOOT { ALL | <bay#> [{ - | , } <bay#>]}
Description
Displays the boot order and one-time boot device for the specified server or range of servers. These
settings correspond to the server boot settings in the ROM-Based Setup Utility.
Restrictions
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning that the blade is not present if this command is used when enclosure power is off.
SHOW SERVER INFO
Syntax
SHOW SERVER INFO { ALL | <bay#>[{ , | - } <bay#>]}
Description
Displays a description of the server blade hardware, including the embedded NICs, the Mezz
HBAs, and the management processor, in the specified bays.
Restrictions
This command functions only if the enclosure power is already on.
Server management 151