Administrator's Guide
SHOW FRU
Syntax
SHOW FRU
Description
Displays summary information on field replaceable units (FRUs) within the enclosure. Information
provided in this section can quickly aid the administrator in contacting HP Customer Service for
troubleshooting, repair, and ordering replacements.
Restrictions
• Only displays known/live data.
• Some FRU devices are not accessible by the EM when the enclosure power is off so their
information is unavailable.
SHOW IOMODULES
Syntax
SHOW IOMODULES
Description
Shows information for the IO modules within the enclosure: SAS, LOM, MEZZ, and PCIe.
Restrictions
• Should be used only when enclosure power is on.
• If enclosure power has never been turned on, no information is available. If it was on but is
now off, only the firmware version of the IO modules that have firmware is shown.
SHOW RACK
Syntax
SHOW RACK { NAME | ID }
Description
Displays user-defined rack name (string) or id (0...255) that is part of the persistent EMU
configuration.
Restrictions
• If rack name has not been set, it is UnnamedRack.
• If rack id has not been set, it is 0.
SHOW SERVER TEMP
Syntax
SHOW SERVER TEMP { ALL | <bay#>[ { , | - } <bay#>] }
Description
Displays temperature sensor information for the specified server or range of servers. This data is
provided by iLO to the EM, which has no direct sensor access.
146 Managing the EMU