Administrator's Guide

Description
Displays the following general information and current status for the specified power supply or
range of power supplies:
Status (OK, Degraded, Dormant, Failed, Unnown)
AC Input status
Capacity: (watts)
Current power output (watts)
Serial Number
Product name
Part number
Spare part number
Product version. Integer value, 01, 02, and so forth.
Restrictions
None
SHOW ENCLOSURE STATUS
Syntax
SHOW ENCLOSURE STATUS
Description
Displays the basic health and status of the enclosure and its subsystems. If the enclosure shows
degraded, the subsystems causing the state change are detailed (for example, failed or missing
redundant module).
Restrictions
None
SHOW ENCLOSURE TEMP
Syntax
SHOW ENCLOSURE TEMP
Description
Displays current status and reading of some of the thermal sensors in the enclosure. If the sensor
is unreadable due to absence of power or failure, ? is displayed.
Restrictions
Only integral measurements in Celsius are displayed (fraction, if any, is truncated).
Not every sensor that is present in the enclosure is reported.
For blades a virtual ambient (not a physical) sensor temperature is displayed that is computed
by iLO based on its thermal model and measurements from several sensors. This model is
transparent to the EM. Until this calculation normalizes, 0 is shown as the temperature for the
blade, so that right after power on of the enclosure, it takes several seconds before a nonzero
value is shown for the blades while other sensors are reported immediately.
Inventory and status 145