Administrator's Guide
Restrictions
None
SHOW ENCLOSURE DRIVE DRAWER
Syntax
SHOW ENCLOSURE DRIVE DRAWER
Description
Displays the state of the enclosure drive drawer. State values are Open, Closed, or Unknown.
SHOW ENCLOSURE FAN
Syntax
SHOW ENCLOSURE FAN { ALL | <fan number> }
Description
Displays information about and current status of the specified enclosure fan.
Restrictions
• The <fan number> must be 1 or 2.
• Fan information is not available if fan status is Dormant (meaning not powered).
• The EM is only directly controlling FAN 1. The JBOD IE expanders control FAN 2 so information
on FAN 2 can only be reported if the enclosure power is on AND at least one SAS IO module
is present and functioning normally.
• Not all information (for example, part number and serial number) of FAN 2 are reported to
the EM by the SAS IO module so it cannot be reported as with FAN 1.
• When the enclosure power is first turned on, FAN 2 status changes from Dormant to Absent
and then to the actual status when this information is given to the EM.
SHOW ENCLOSURE INFO
Syntax
SHOW ENCLOSURE INFO
Description
Displays information about the enclosure and included options.
NOTE: Some information, such as Enclosure Name, is user supplied, and if never programmed,
has a default value. The Solution part number, serial number and name string are programmed in
the factory depending on the software SKU that is pre-installed. These numbers and strings are not
customer programmable but vary by solution SKU even if the hardware is the same type. The
solution numbers, not the chassis numbers, are used for warranty obligation tracking.
Restrictions
None
SHOW ENCLOSURE POWERSUPPLY
Syntax
SHOW ENCLOSURE POWERSUPPLY { ALL | <bay> { , | - } <bay>}
144 Managing the EMU