Administrator's Guide

Table 15 Universal time zone settings (continued)
WSUGreenwichEtc/GMT+11Etc/GMT-6Etc/GMT+0
ZuluHSTEtc/GMT-12Etc/GMT+6Etc/GMT-1
METEtc/GMT+12Etc/GMT-7Etc/GMT+1
If you leave the time zone, century, or year blank, the current setting is reused.
Restrictions
Date and time can only be set if NTP is disabled.
MM is an integer from 01 to 12.
DD is an integer from 01 to 31.
hh is an integer from 00 to 23.
mm is an integer from 00 to 59.
CC is an integer from 00 to 99.
YY is an integer from 00 to 99.
SET TIMEZONE
Syntax
SET TIMEZONE <timezone>
Description
Sets the time zone.
Restrictions
Only the choices listed in Table 15 (page 139) can be used.
SET NTP POLL
Syntax
SET NTP POLL <seconds>
Description
Sets the polling interval for NTP servers. The factory default polling interval is 720 seconds (12
minutes).
Restrictions
The polling range is 60 – 86400 seconds (1 minute to 1 day).
NOTE: EM 1.10 or later does not support this command.
SET NTP PRIMARY
Syntax
SET NTP PRIMARY <host>
Description
Sets the primary server used for synchronizing time/date using the Network Time Protocol (NTP).
<host> can be either an IPv4 address, an IPv6 address, or a DNS name.
140 Managing the EMU