Getting Started Guide

1-6
Hardware Overview and Quick Start Installation and Initial Setup
Hardware
Electrical
The DCM Controller automatically adjusts to any voltage between 100–127
and 200–240 volts and either 50 or 60 Hz. (See Table 1-2.)
Table 1-2. Electrical Specifications
Environmental Guidelines
Table 1-3 lists the environmental guidelines for the DCM Controller.
Table 1-3. Environmental
Acoustic
Noise Emission LwA=52 dB at virtual work space according to DIN 45635 T.19.
(Geraeuschemission LwA=52 dB am fiktiven Arbeitsplatz nach DIN 45635
T.19 .)
USB Port
The DCM Controller has a USB port, which supports USB 2.0-compliant drives.
However, the USB port does not support USB 3.0-compliant drives.
You use the USB port to back up and restore data and to re-initialize DCM
Controller in the event of catastrophic failure. (For more information, see
Appendix A, “Back up, Restore, and Re-initialize the HP Datacenter Connec-
tion Manager (DCM) Controller.”)
AC voltage 100–127/200–240 volts
Maximum current 2A/1A
Frequency range 50/60 Hz
Operating Non-Operating
Temperature 5°C to 40°C (41°F to 122°F) –40°C to 65°C (–40°F to 149°F)
Relative humidity:
(non-condensing)
15% to 80% at 40°C (104°F) 20% to 90% at 65°C (149°F)
Maximum altitude 2 km (6,500 ft) 4.6 km (15,000 ft)