HP Smart Array B110i SATA RAID Controller User Guide Part Number 531480-003 March 2010 (Third Edition)
© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S.
Contents Enabling and configuring the controller ........................................................................................... 5 Enabling the controller and setting the boot order ............................................................................................ 5 HP ProLiant 100 Series servers ............................................................................................................ 5 HP ProLiant 300 Series servers ..................................................
Index .........................................................................................................................................
Enabling and configuring the controller Enabling the controller and setting the boot order The HP Smart Array B110i SATA RAID Controller is not enabled by default and must be enabled in RBSU. For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). HP ProLiant 100 Series servers To enable the controller and set boot order: 1. Power up the server. 2.
Configuring an array The HP Smart Array B110i SATA RAID Controller supports SATA drives only. For the most efficient use of drive space, all drives within an array should have approximately the same capacity. Each configuration utility treats every physical drive in an array as if it has the same capacity as the smallest drive in the array. Any excess capacity of a particular drive cannot be used in the array. Therefore, the capacity is unavailable for data storage.
6. Press the F8 key to confirm the settings and save the new configuration. After several seconds, the Configuration Saved screen appears. 7. Press the Enter key to continue. Repeat this procedure to create additional logical drives.
IMPORTANT: The license key is stored on the hard drive. If no hard drives are installed, the license key cannot be installed. Before installing the license key, be sure that hard drives are installed. For more information on installing hard drives, see the server user guide. To obtain the license key, see the entitlement certificate included with the HP Hot Plug Advanced Pack. Depending on the method of delivery, the certificate is provided either in a sealed envelope or in an email message.
The ORCA main menu appears. 4. Select Manage License Keys. IMPORTANT: If no hard drives are installed, then this option does not appear. 5. Under the License Key menu, select Add License Key. 6. Enter the license key in the space provided. ORCA issues a notification after the license key activates successfully. Installing a license key with ACU To install a license key: 1. Power down the server, if necessary. 2. Power up the server.
3. Open ACU. 4. Select a controller from the Controller/Device menu. The System Status, Systems And Devices, and Available Tasks panels appear. 5. In the Available Tasks panel, click Manage License Keys. IMPORTANT: If no hard drives are installed, then this option does not appear. Specific license key tasks appear. A complete list of existing license keys also appears. 6. Click Add License Key. 7. Enter the license key number. 8. Click Save.
Installing device drivers and Management Agents Installing device drivers IMPORTANT: Enable the HP Smart Array B110i SATA RAID Controller before installing device drivers. For more information see "Enabling the controller and setting the boot order (on page 5)." A device driver is required for the operating system to communicate with the disk drive controller. For more information on supported operating systems, see the HP Smart Array B110i SATA RAID Controller product page on the HP website (http://www.hp.
You can update the Management Agents by using the latest versions of the agents provided on the SmartStart CD or the Easy Set-up CD. The procedure is provided with the agents. To download the latest versions of the CDs, see the HP website: • SmartStart CD (http://h18013.www1.hp.com/products/servers/management/smartstart/documentation.html?jumpi d=hpr_R1002_USEN). • Easy Set-up CD (http://h18013.www1.hp.com/products/servers/management/remotemgmt/easy_setup_cd/index.h tml?jumpid=reg_R1002_USEN).
Replacing, moving, or adding hard drives Recognizing hard drive failure CAUTION: Sometimes, a drive that has previously been failed by the controller may seem to be operational after the system is power-cycled or (for a hot-pluggable drive) after the drive has been removed and reinserted. However, continued use of such marginal drives may eventually result in data loss. Replace the marginal drive as soon as possible.
• RAID 0 configurations cannot tolerate drive failure. If any physical drive in the array fails, all RAID 0 logical drives in the same array also fail. • RAID 1 configurations can tolerate one drive failure. If one physical drive in a RAID 1 configuration fails, the RAID volume is still intact as a degraded RAID 1. • RAID 1+0 configurations can tolerate up to two drive failures as long as no failed drives are mirrored to one another.
Replacing hard drives If you are replacing a drive in a fault-tolerant configuration while the system is powered down, a POST message appears when the system is powered up. When this message appears, press the F1 key to enable automatic data recovery. If you do not enable automatic data recovery, the logical volume remains in a ready-to-recover condition, and the same POST message appears when the system is restarted. In RAID 1 configurations, you can replace one failed drive.
• The brand, model, and age of the drives • The amount of unused capacity on the drives Allow approximately 15 minutes per gigabyte for the rebuild process to complete. System performance is affected during the rebuild, and the system is unprotected against further drive failure until the rebuild has finished. Therefore, replace drives during periods of low activity, when possible.
You might be able to enable a recently failed drive temporarily by cycling the server power. To cycle the server power: 1. Power down the server. 2. Remove the replacement physical drive (the one undergoing a rebuild), and then reinstall the drive that it is replacing. 3. Power up the server. If the newly failed drive is operational, do the following: 1. Back up any unsaved data. 2. Remove the original drive that was being replaced, and then reinsert the replacement physical drive.
2. Power down the system. 3. Move the drives. 4. Power up the system. 5. Observe the POST messages: 6. o If a 1785 POST message appears, the drive array did not configure properly. Continue with step 6. o If a 1724 or 1727 POST message appears, drive positions were changed successfully and the configuration was updated. Continue with step 7. If the array did not configure properly, do the following: a. Power down the system immediately to prevent data loss. b.
Migrating hard drives to an optional Smart Array controller Installing an optional Smart Array controller To install the component: 1. Power down the server. 2. Remove the access panel. 3. Remove components and cables as needed. 4. Install the Smart Array controller. For more information, see the server user guide or the documentation that ships with the option. 5. Install components and cables removed previously. 6. Install the access panel. 7. Power up the server. 8.
To install the driver from the Easy Set-up CD: 1. From the System Support Software menu, select the current operating system. 2. Select Driver – storage controller. 3. Download the HP ProLiant Smart Array SAS/SATA Controller Driver package. 4. To install the driver, run the Smart Array Controller package. When the driver is installed, complete the migration procedure.
For more information about installing SLES by label, see the OS documentation for SLES. Installing the Smart Array driver—Linux To install the Smart Array driver: 1. Using the software RAID controller, boot the operating system. 2. Download the latest Smart Array hpahcisr driver from the HP website (http://www.hp.com/go/support): a. When prompted for product information, enter the Smart Array controller model number in the product field. b. Select Download drivers and software. c.
Diagnosing array problems Diagnostic tools To troubleshoot array problems and generate feedback about arrays, use the following diagnostic tools: • ACU For more recent products, array diagnostics is available with ACU v8.28.13.0 and later. This utility is available on the SmartStart CD in the controller kit and also on the HP website (http://www.hp.com/support).
Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: • Avoid hand contact by transporting and storing products in static-safe containers.
Regulatory compliance notices Battery replacement notice This component uses a nickel metal hydride (NiMH) battery pack. WARNING: There is a risk of explosion, fire, or personal injury if a battery pack is mishandled. To reduce this risk: • Do not attempt to recharge the batteries if they are disconnected from the controller. • Do not expose the battery pack to water, or to temperatures higher than 60°C (140°F). • Do not abuse, disassemble, crush, or puncture the battery pack.
Acronyms and abbreviations ACU Array Configuration Utility ADU Array Diagnostics Utility IML Integrated Management Log ORCA Option ROM Configuration for Arrays POST Power-On Self Test RBSU ROM-Based Setup Utility SIM Systems Insight Manager SMHP HP System Management Homepage Acronyms and abbreviations 25
Index A H activating an array 5 activation 5 ACU (Array Configuration Utility) 6, 11, 13, 15, 16, 18 adding drives 18 ADU (Array Diagnostic Utility) 13, 22 Array Configuration Utility (ACU) 6, 7, 13, 15, 16, 17 Array Diagnostic Utility (ADU) 13, 22 array expansion 18 array, moving 17 automatic data recovery (rebuild) 15 hard drive failure, effects of 13 hard drive, failure of 13 hard drive, replacing 15 hard drives, adding 18 hard drives, moving 17 HP Insight Diagnostics 22 HP SIM 11, 13 HP Systems Insig
S Smart Array controller, installing 19 Smart Array driver, installing 19, 21 static electricity 23 T Taiwan battery recycling notice 24 troubleshooting 22 U updating Management Agents 11 Index 27