Reference Guide
7.4.5 HPSA_StorageVolume.FaultTolerance
Enumeration to indicate which type of raid is currently configured for a logical volume. Supported values
are:
Table 26 - HP Smart Array profile: HPSA_StorageVolume.FaultTolerance
Value ValueMap
0
Unknown
1
RAID 0
2
RAID 1
3
RAID 1+0
4
RAID 4
5
RAID 5
6
RAID 51
7
RAID 6
8
RAID 50
9
RAID 60
10
RAID 1 (ADM)
11
RAID 10 (ADM)
7.4.6 HPSA_StorageVolume.OperationalStatus
OperationalStatus values have been extended to add Smart Array specific values for Logical Volume
status.
The extended values shall be populated in OperationalStatus[1] and the equivalent DMTF defined status
will be populated in OperationalStatus[0] as specified in Table . Note these extended values will more
accurately define the storage volume’s status when in a degraded state.
Table 27 - HP Smart Array profile: HPSA_StorageVolume.OperationalStatus – Extended values
Value ValueMap OperationalStatus[0]
0x8000
Physical Drive improperly connected
Degraded (3)
0x8001
Expanding
Degraded (3)
0x8002
Overheated
Degraded (3)
0x8003
Overheating
Degraded (3)
0x8004
Interim Recovery
Degraded (3)
0x8005
Not Configured
Degraded (3)
0x8006
Not Yet Available
Degraded (3)
0x8007
Queued For Expansion
Degraded (3)
0x8008
Ready For Recovery
Degraded (3)
0x8009
Recovering
Degraded (3)
0x800A
Wrong Drive Replaced
Degraded (3)
0x8015
Logical drive disabled due to SCSI ID
conflict
Degraded (3)
0x8016
Logical drive has been ejected
Degraded (3)
Table 28 - HP Smart Array profile: HPSA_StorageVolume.OperationalStatus[1]
The below OperationalStatus[1] reflects the Secondary (OR) Extended status of the logical volume which
participate in the Secure Erase Operation.
Version 2.13.1 53