Reference Guide

Version 1.0.2 11
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 CIM Elements HP Power Supply Profile
Element Name
Requirement
Description
Classes
HP_PowerSupplyModule
Mandatory
See Sections 7.1 and 10.1
HP_RegisteredProfile
Mandatory
See Section 10.2
HP_RealizesPowerSupply
Mandatory
See Sections 7.2 and 10.3
HP_SystemPhysicalPowerSupply
Mandatory
See Sections 7.3 and 10.4
HP_PowerSupplyInSlot
Conditional
See Sections 7.4 and 10.5
Indications
None defined in this profile
10.1 HP_PowerSupplyModule
HP_PowerSupplyModule is used to represent a power supply module in a managed system.
Table 3 Class: HP_PowerSupplyModule
Properties
Requirement
Notes
RemovalConditions
Mandatory
See Section 7.1.1
10.2 HP_RegisteredProfile
The HP_RegisteredProfile class is defined by the HP Profile Registration Profile.
Table 4 Class: HP_RegisteredProfile
Properties
Requirement
Description
RegisteredName
Mandatory
"HP Power Supply Physical Asset"
RegisteredVersion
Mandatory
“1.0.2
RegisteredOrganization
Mandatory
Other (1)
OtherRegisteredOrganization
Mandatory
“HP WBEM TC”
10.3 HP_RealizesPowerSupply
HP_RealizesPowerSupply is used to represent the association between HP_PowerSupply and
HP_PowerSupplyModule.
Table 5 Class: HP_RealizesPowerSupply
Properties
Requirement
Notes
Antecedent
Mandatory
Key: References HP_PowerSupplyModule
Dependent
Mandatory
Key: References HP_PowerSupply