Reference Guide
Version 1.1.0 11
9.2 Retrieve the Fan Status for a Fan Module
For the given instance of HP_FanModule, retrieve associated instances of HP_Fan through the
HP_RealizesFan association. Observe the HP_Fan.OperationalStatus property for this instance.
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 – CIM Elements – HP Fan Profile
Element Name
Requirement
Description
Classes
HP_FanModule
Mandatory
See Sections 7.1 and 10.1
HP_RegisteredProfile
Mandatory
See Section 10.2
HP_RealizesFan
Mandatory
See Sections 7.2 and 10.3
HP_SystemPhysicalFan
Mandatory
See Sections 7.3 and 10.4
HP_FanInSlot
Conditional
See Sections 7.4 and 10.5
CIM_Slot
Optional
See Section 7.5
Indications
None defined in this profile
10.1 HP_FanModule
HP_FanModule is used to represent a fan module in a managed system.
Table 3 – Class: HP_FanModule
Properties
Requirement
Notes
RemovalConditions
Mandatory
See Section 7.1.1
Description
Optional
See Section 7.1.2
10.2 HP_RegisteredProfile
The HP_RegisteredProfile class is defined by the HP Profile Registration Profile.
Table 4 – Class: HP_RegisteredProfile
Properties
Requirement
Description
RegisteredName
Mandatory
"HP Fan Physical Asset"
RegisteredVersion
Mandatory
“1.1.0”
RegisteredOrganization
Mandatory
Other (1)