Reference Guide

18 Version 1.3.0
Retrieve the Power Supply Group Operational Status
For the given instance of HP_PowerSupply, select the associated instance of HP_PowerCollection
through HP_MemberOfPowerCollection association. Retrieve the value of
HP_PowerCollection.GroupOperationalStatus property.
9.2 Retrieve the Power Supply Redundancy Status
For the given instance of HP_PowerSupply, select the associated instance of HP_PowerRedundancySet
through HP_MemberOfPowerRedundancy association. Retrieve the value of
HP_PowerRedundancySet.RedundancyStatus property.
9.3 Determine the Type of Power Collection
For the given instance of HP_PowerCollection, select an associated instance of HP_PowerSupply
through HP_MemberOfPowerCollection association. The type of Power Collection is described by the
associated HP_PowerSupply.PowerSupplyType property enumeration.
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 CIM Elements HP Power Supply Profile
Element Name
Requirement
Description
Classes
HP_PowerSupply
Mandatory
See Sections 7.1 and 10.1
HP_RegisteredProfile
Mandatory
See Section 10.2
HP_PowerCollection
Optional
See Sections 7.3 and 10.3
HP_PowerRedundancySet
Optional
See Sections 7.1.4 and 10.4
HP_MemberOfPowerRedundancy
Conditional
See Sections 7.5 and 10.5
HP_MemberOfPowerCollection
Conditional
See Sections 7.7 and 10.8
HP_HostedPowerRedundancySet
Conditional
See Sections 7.6 and 10.6
HP_HostedPowerCollection
Conditional
See Sections 7.8 and 10.9
HP_SystemPowerSupply
Mandatory
See Sections 7.4 and 10.11
HP_SuppliesPower
Optional
See Sections 7.9 and 10.12
Indications
None defined in this profile
10.1 HP_PowerSupply
HP_PowerSupply is used to represent a power supply in a managed system.