Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)
Operation 2-25
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
c-ch2 Operation.doc
Last Saved On:
7/12/00 10:51 AM
Displaying Error Logs
To display the error history of the module, you need to use the Show History
menu. Access this menu as follows:
Fault Code: XXXX
Error Description
DD/MMM/YYYY HH:MM:SS
Entry NNNN Of NNNN
Loading and Unloading Tapes
The Load/Unload menus let you specify a source and a destination for a
cartridge movement. As a result, you use exactly the same procedure to load
and unload. To load or unload a tape from the front panel of the module, use
the Load/Unload menus.
The following Default screen appears. From this screen, enter Menu Mode by
pressing the
Enter
button.
READY
Modules 012345_
0
_ _ _ _ _ _ _ _ 9
10
_ _ _ _ _ 16
Afterwards, the Main menu appears:
Load/Unload
Show Status Menu
Maintenance Menu
Configure Menu
The is next to the line that reads Load/Unload. Press the
Enter
button to
display the first Load/Unload submenu, which is shown below:
From:
DLT1
To:
*Slot3