Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)

2-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Compaq Confidential Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
c-ch2 Operation.doc
Last Saved On:
7/12/00 10:51 AM
The first line shows a numerical FSC. The second line shows a brief
description of the error, in place of the words, “Error Description.” The third
and fourth lines contain a one- or two-line message describing the initial ERP
in place of the words shown in the Fault screen.
A list of FSC and ERP appears in Chapter 6, “Diagnostics and
Troubleshooting.”
MiniLibrary Base Module Default Screen
The MiniLibrary Base Modules display a different Default screen, as shown:
DLT0 Seeking
DLT1 Idle
Loader Idle
16
_ _ _ _ _ _ _ _
25
The example shown is a Base Module in the module 1 position. The first and
second lines of the Default screen show the status of the two drives within the
Base Module. On line 4, a rectangle appears in each position that contains a
cartridge. An underline appears at each empty slot. The numbers at the
beginning and end of line 4 represent the numbers the system has assigned to
the first and last slots of that module.
The possible status conditions of the drives are:
No tape
Idle
Rewinding
Seeking
Reading
Writing
Erasing
Cleaning
Unloaded
Loading
Unloading