Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)
Operation 2-13
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
c-ch2 Operation.doc
Last Saved On:
7/12/00 10:51 AM
Initialization Screens
After POST completes, the library robotics system is initialized. A series of
screens similar to the following appears during this process:
COMPAQ TL89x
Firmware Level 0X.xx
Initializing Loader
26-Feb-19xx 15:35:59
Default Screen
After the POST diagnostics have concluded successfully and initialization is
complete, the system Default screen appears:
READY
Modules:0_ _ _ _ _ _
0
_ _ _ _ _ _ _ _ 9
10
_ _ _ _ 15
The numbers on the second line correspond to the Base Modules that are
connected to the system. Up to five Base Modules can be connected. The third
and fourth lines represent the cartridge magazine in the Expansion Unit. A
rectangle appears in each position that contains a cartridge. An underline
represents an empty slot.
Fault Screen
When a fault is detected within the Expansion Unit or the Pass-Through
Mechanism (PTM), a screen similar to the following appears:
Fault Code: XXXX
Error Description
ERP line 1
ERP line 2
When a fault is detected in one of the Base Modules, the Alert LED on the
Expansion Unit control panel lights and the Fault screen appears on the
malfunctioning Base Module. At the same time, either the Drive Fault or the
Loader Fault LED lights on that module.