Appendix
G
Interconnect Characteristics for Signals
Table G-1
Recommended Minimum Conductor Size
SE LVD HVD
3 m Cable 6 m Cable 12 m Cable >12 m Cable 25 m Cable
All conductors
except terminator
power and
reserved
0,050 92 mm
2
(30 AWG)
0,080 42 mm
2
(28 AWG)
0,032 4 mm
2
(32 AWG)
0,080 42 mm
2
(28 AWG)
0,050 92 mm
2
(30 AWG)
Single terminator
power line
0,080 42 mm
2
(28 AWG)
0,080 42 mm
2
(28 AWG)
N/A N/A N/A
Multiple
terminator power
lines
0,050 92 mm
2
(30 AWG)
0,050 92 mm
2
(30 AWG)
0,032 4 mm
2
(32 AWG)
0,080 42 mm
2
(28 AWG)
0,050 92 mm
2
(30 AWG)
NOTE:
1.
SE 6 m cable applies to SCSI devices running at or below fast-5 data transfer rates.
2.
For interconnects supporting LVD/SE multimode, the larger conductor size should be
used.
3.
The conductor size recommendations assume voltage drops only due to the cables
(that is, they do not include voltage drops due to connectors, ground effects, and so
on).