Table 6-8
Intermodule Error Codes (6xxx)
FSC Message Description
6001 Comm Open Error An attempt to open the RS-232 serial
communication port used by the inter-module
processes failed.
6002 Comm Port Send Error An inter-module process (Master or Slave) was
sending a packet to a remote module, but the UART
detected an error condition during the transfer.
6003 Comm Port Recv Error An inter-module process (Master or Slave) was
receiving a packet from a remote module, but the
UART detected an error condition during the transfer.
6004 EnQ Without IDs
6005 DeQ Without Ids
6006 EnQ Null Pointer
6007 No Free Comm Blks
6010 Pkt Send Error The Master inter-module process has repeatedly
attempted to send a packet to a Slave inter-module
process, but all retries have been exhausted before
the packet could be successfully sent.
6011 Pkt Receive Error The Master inter-module process has repeatedly
attempted to receive a packet from a Slave inter-
module process, but all retries have been exhausted
before the packet could be successfully received.
6012 Status Unexpected The Master inter-module process received a Status
packet, but no command is currently active.
6013 Invalid Com Blk Type The Master inter-module process received a packet
from a Slave inter-module process, but the packet’s
CommBlock type was invalid.
6014 Invalid Com Blk Type The Master inter-module process received a packet
from the Command/Message queue, but the
packet’s CommBlock type was invalid.
continued