Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)
6-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
g-ch6 Diagnostics and Troubleshooting.doc
Last Saved On:
7/12/00 11:32 AM
Table 6-5
Motor Process Error Codes (3xxx)
continued
FSC Message Description
3103 Picker Jammed While stowing to a bin, the picker moved too far.
This generally occurs if the arm slips in between two
cartridges during the final push.
3104 Picker Jammed During a bin stow, the picker did not reach a position
far enough to insure that the cartridge was fully
inserted.
3105 Picker Jammed The picker was not able to home properly after
stowing a cartridge to a bin.
3106 Picker Jammed The picker was not able to position to the cartridge
notch while performing a bin fetch operation.
3107 Picker Jammed During a bin fetch, the picker stalled while
attempting to pull a cartridge into the shuttle.
3108 Picker Jammed The picker stalled while fetching from a bin.
3109 Picker Jammed The picker was not able to position to the cartridge
notch while performing a drive fetch operation.
310A Picker Jammed During a drive fetch, the picker stalled while
attempting to pull a cartridge into the shuttle.
310B Picker Jammed During a stow operation, the picker was not able to
insert the cartridge into the drive.
3200 Elevator Jammed The elevator was not able to position properly while
attempting to recover an orphaned cartridge.
3201 Elevator Jammed The elevator was not able to position properly during
an inventory.
3202 Elevator Jammed The elevator was not able to position properly during
a fetch operation.
3203 Elevator Jammed The elevator was not able to position properly during
a stow operation.
3204 Elevator Jammed The elevator was not able to position properly during
a home operation.
3205 Elevator Jammed The elevator stalled while attempting to open the
DLT door.
3300 Passthru Jammed The pass-through elevator was not able to position
properly.