Table 6-4
Control Error Codes (2xxx)
continued
FSC Message Description
2073 Drive Config Error Set if the Alternate Unload has not been selected.
This currently applies only to DLT7000’s and
DLT8000’s with a controller microcode revision
greater than 50.
2074 Stow Error A stow timeout error has occurred when accessing a
remote unit. Press the
Enter
button to reboot for
orphan cartridge recovery.
2075 Fetch Error During a remote fetch operation, the remote unit
returned an error.
Table 6-5
Motor Process Error Codes (3xxx)
FSC Message Description
3001 Picker Retries Exceeded Remove from code.
3002 Picker Tach Errors TACH errors were detected during a picker
movement.
3003 Elevator Tach Errors TACH errors were detected during an elevator
movement.
3004 Elevator Init Error An elevator jam was detected during initialization.
3006 Passthru Tach Errors TACH errors were detected during pass-through
elevator movement.
3007 DLT Timeout Error Communication with one of the DLT drives was
unsuccessful.. A command was issued but status
was not returned.
3008 Invalid Drive State Currently unused.
3009 Door Tach Errors TACH errors were detected during a door movement.
300A Door Fault During initialization, the door was found to be in an
improper state.
300B Elev Open Tach Open Tach detected on elevator motor.
continued