Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)
Configuration 4-7
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
e-ch4 Configuration.doc
Last Saved On:
7/12/00 11:09 AM
The following Special Config submenu appears:
Mode Pg 1F Length
* Short (0x0E)
Model Number
* Compaq TL89X
Press twice to position the next to the TUR Reporting option. Press
the
Enter
button to move
down one line to *Standard. Use the to
change to Custom and press the
Enter
button to accept this setting. To
return the Base Module to online status, press the
Escape
button
three
times.
Set Element Base
This option lets you set the base addresses of each of the three SCSI elements
of the module. In order to identify sources and destinations in commands to
the robotics, the Base Module is divided into elements, each of which is
assigned a separate designator or element address. The transport element is the
robotics mechanism itself; the storage elements are the 10 or 16 slots in the
magazine; the transfer elements are the drives. The Base Module reports these
settings in response to the SCSI MODE SENSE command, in the element
address assignment page. The defaults are transport = 0000h, storage element
base = 0001h, transfer element base = 00F0h.