Upgrading Compaq ProLiant Clusters HA/F100 and HA/F200

Upgrading Compaq ProLiant Clusters HA/F100 and HA/F200 38
13XT-0401B-WWEN
current version of the driver on the node or due to a lack of hardware on the
node.
9. Install Windows 2000 Service Pack 1 on Node 1 and reboot when prompted.
10. Verify that the Cluster Service has started and that Node 1 has rejoined the cluster.
a. Open Cluster Administrator by clicking Start, Programs, Administrative Tools,
Cluster Administrator.
b. As the Cluster Administrator opens, an error may display. (This error is a result
of the additional resources that Windows 2000 Advanced Server offers Microsoft
Cluster Server. This error will not display when Node 2 is upgraded to Windows
2000 Advanced Server).
c. From the error screen, select Yes To All to open Cluster Administrator.
11. Install New Hardware:
a. Shut down node 1 and install the second host bus adapter, additional redundant
RA4000 Controllers, the additional Fibre Channel storage hub or FC-AL switch
and cables as necessary.
IMPORTANT: To ensure that your HA/F200 cluster fails over properly, attach each host bus
adapter in a single server to a different Fibre Channel storage hub or FC-AL switch, and attach
each RA4000 Controller in the RA4000/4100 to a different Fibre Channel storage hub or FC-AL
switch.
IMPORTANT: If using the Compaq StorageWorks FC-AL Switch 8, be sure to properly set up
the Port LIP Propagation Policies correctly. Refer to the product documentation for the
StorageWorks FC-AL Switch for this information.