Upgrading Compaq ProLiant Clusters HA/F100 and HA/F200

Upgrading Compaq ProLiant Clusters HA/F100 and HA/F200 30
13XT-0401B-WWEN
Migration Scenario 4:
HA/F100 Windows NTS/E to HA/F200 Windows 2000
Advanced Server
The migration of HA/F100 Windows NTS/E to HA/F200 Windows 2000 Advanced Server can
be performed while keeping your cluster on-line (a rolling upgrade) provided that the firmware
levels of all RA4000 controllers are at the same level of v2.58 or later.
IMPORTANT: Back up all data before beginning the migration process.
IMPORTANT: Prior to beginning this migration, both nodes running Windows NTS/E must
have Service Pack 6a for Windows NTS/E installed.
IMPORTANT: If upgrading to version 3.1a of Secure Path for Windows 2000 on RAID Array
4000/4100 then please make sure to upgrade to SmartStart 5.00 and Compaq StorageWorks
RA4100 San Solution Support Software - 5.01. This newer version of Secure Path is not
compatible with older drivers found on SmartStart 4.90 or earlier.
The basic steps to this rolling upgrade include:
1. Verify the Controller Firmware Levels
2. Make sure that all components are present for the second Fibre Channel loop
3. Move all cluster resources over to node 2
4. Remove any cluster fixes that may be installed
5. Run Compaq Primer Utility
6. Apply Service Pack 6a on node 1 again
7. Upgrade the operating system and drivers on node 1
8. Add the redundant loop hardware
9. Upgrade the hardware on node 1
10. Install Secure Path on node 1
11. Move all cluster resources back to node 1
12. Upgrade the operating system and drivers on node 2
13. Upgrade the hardware on node 2
14. Install Secure Path on Node 2