Cisco NX-OS System Messages Reference (OL-15994-03, July 2009)
Send document comments to nexus7k-feedback-doc@cisco.com
2-719
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SYSTEMHEALTH Messages
Error Message SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_FAILED: Compact Flash firmware CRC
checksum on module [dec] is corrupted.
Explanation Compact flash firmware has been corrupted.
Recommended Action Replace the compact flash on this module.
Error Message SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_INIT_ERRORS: Compact Flash firmware
CRC checksum procedure encountered an error during initialization on module [dec],
reason:([chars]).
Explanation Compact flash CRC checksum initializations failed.
Recommended Action Check the compact flash on the board and any relevant system
(mis)configurations.
Error Message SYSTEMHEALTH-2-OHMS_SUP_CF_REFLASH_FAILED: Compact Flash firmware
refresh procedure failed, replace the compact flash on module [dec]. Reason [dec]
Explanation Compact flash firmware has been corrupted is corrupted.
Recommended Action Replace the compact flash on this module.
Error Message SYSTEMHEALTH-2-OHMS_SWITCH_RELOAD_REQ: Switch reload request due to
errors found [chars] test.
Explanation The system Health Switch Reload Request.
Recommended Action No action is required.
Error Message SYSTEMHEALTH-2-OHMS_SWITCHOVER_REQ: Supervisor switch over being
requested due to errors found [chars] test.
Explanation The system Health Switch Over Request.
Recommended Action No action is required.
Error Message SYSTEMHEALTH-2-OHMS_TCAM_PARITY_FAILED: TCAM test failed for module
[dec].
Explanation TCAM test failed for module as uncorrectable parity errors were detected.
Recommended Action Please schedule a downtime and replace the module.