Table 8 lists the caveats that are resolved in Cisco NX-OS Release 5.0(3)N2(2). The caveats may be open
in previous Cisco NX-OS releases.
CFS
CSCsl73766 RADIUS configuration distribution via CFS is unsupported.
CSCsm16222 Roles configuration distribution via CFS is unsupported.
CSCsr35452 CFS-based distribution of the NTP peer configuration does not work.
CSCtb34546 Peer switches gets stuck in CFS discovery when you enter the deny all ip pkts
mgmt0 command.
Fabric Extender
CSCsv15775 The priority-tagged frames on FEX ports get dropped.
CSCsv93263 FEX port configurations are lost when a configuration restore is done after a write
erase and reload.
CSCsx68778 Flowcontrol configuration on the FEX ports may fail when the range command is
used with interfaces that are spread across FEXs.
CSCta04383 The FEX should automatically revert to an older image if a second switch boots with
the same version.
Transceiver
CSCsv00989 Transceiver details are read as zeros even on DOM-capable 1G SFPs.
CSCsv02866 The show interface ethernet transceiver details command may show "invalid
calibration" for DOM supported 1G SFPs.
Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued)
Record Number Open Caveat Headline
Table 7 Cisco NX-OS 5.0(3)N2(2) Resolved Caveats
Record Number Resolved Caveat Headline
CSCtq60360
A remote user name with "@" in the username field, fails authentication.
CSCtq60920 Fabric interfaces sdp timeout occurs on a reload with a new reserved VLAN.
CSCtq86334 Traffic is not load-balanced on port channel links on a Nexus 2248 Fabric Extender
and on a Nexus 5548 switch.
CSCtr10164 On Nexus 5000 Series switches, an ospfv2 memory leak may occur when receiving
specific malformed packets.
CSCtr17962 Turning on SVI on an access switch causes data forwarding that bypasses the
flexlink blocked link.
CSCtr27823 A host interface in a port channe does not come up.
CSCtr37490 Switch use different bridge ID for STP convergion and BPDU