Send documentation comments to nexus5kdocs@cisco.com Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, for Cisco NX-OS Release 5.0(3)N2(2) and Release 5.0(3)N2(1) Release Date: June 13, 2011 Current Release: NX-OS Release 5.0(3)N2(2) Current Release: NX-OS Release 5.0(3)N2(1) This document describes the features, caveats, and limitations for Cisco Cisco Nexus 5000 Series switches and the Cisco Nexus 2000 Series Fabric Extenders.
Contents Send documentation c omment s to nexus5kdocs@cisco.com Table 1 Online History Change Revision Date Description D0 July 19, 2011 Added information about Cisco Nexus 2000 Series 10-Gigabit BASE-T Fabric Extenders and Reversed Airflow and DC Power Options. E0 August 2, 2011 Updated Hardware Supported table and added information about Data Center Network Manager Release 5.2 Support. F0 September 7, 2011 Added CSCto09813 (PSIRT) and CSCts44423. Moved CSCto23248 to Resolved.
System Requirements Send documentation c omment s to nexus5kdocs@cisco.com Cisco Nexus 5000 Series Switches The Cisco Nexus 5000 Series switches include a family of line-rate, low-latency, lossless 10-Gigabit Ethernet, Cisco Data Center Ethernet, Fibre Channel over Ethernet (FCoE), and now native Fibre Channel switches for data center applications. The Cisco Nexus 5000 Series includes the Cisco Nexus 5500 Platform and the Cisco Nexus 5000 Platform.
System Requirements Send documentation c omment s to nexus5kdocs@cisco.com Table 2 Hardware Supported by Cisco NX-OS Release 5.0(x) Software Cisco NX-OS Release Support Hardware Part Number 5.0(3)N2(2) 5.0(3)N2(1) 5.0(3)N1(1) 5.0(2)N2(1) 5.
System Requirements Send documentation c omment s to nexus5kdocs@cisco.com Table 2 Hardware Supported by Cisco NX-OS Release 5.0(x) Software (continued) Cisco NX-OS Release Support Hardware Part Number 5.0(3)N2(2) 5.0(3)N2(1) 5.0(3)N1(1) 5.0(2)N2(1) 5.
New and Changed Features Send documentation c omment s to nexus5kdocs@cisco.com Table 3 Online Insertion and Removable Support by Cisco NX-OS Release 5.0(x) Software Cisco NX-OS Release Support Hardware Part Number 5.0(3)N2(2) 5.0(3)N2(1) 5.0(3)N1(1) 5.0(2)N2(1) 5.
New and Changed Features Send documentation c omment s to nexus5kdocs@cisco.com • 2 Power supplies (AC or DC power supplies). • 1 Fan module with a choice of standard or reversed airflow. Reversed Airflow and DC Power Options The Cisco Nexus 2200 Series Fabric Extenders offer a choice of standard airflow (port-side exhaust) and reversed airflow (port-side intake), as well as a choice for AC and DC power options.
New and Changed Features Send documentation c omment s to nexus5kdocs@cisco.com Fibre Channel over Ethernet N-Port Virtualization Beginning with Cisco NX-OS Release 5.0(3)N2(1), Fibre Channel over Ethernet N-Port Virtualization (FCoE NPV) is supported on the Cisco Nexus 5000 Series switches. The FCoE NPV feature is an enhanced form of FIP snooping that provides a secure method to connect FCoE-capable hosts to an FCoE-capable FCoE forwarder (FCF) switch.
Upgrading or Downgrading to a New Release Send documentation c omment s to nexus5kdocs@cisco.com Auto-Negotiation Disable Beginning with Cisco NX-OS Release 5.0(3)N2(1), you can disable auto-negotiation on a switch port. This feature allows you to connect devices that do not support auto-negotiation (for example, certain DWDM multiplexers) to a Cisco Nexus 5000 Series switch.
Upgrading or Downgrading to a New Release Send documentation c omment s to nexus5kdocs@cisco.com Upgrade and Downgrade Guidelines The following guidelines apply to Cisco NX-OS Release 5.0(3)N2(2) and Release 5.0(3)N2(1) for the Cisco Nexus 5000 Series switches: • Do not change any configuration settings or network settings during the upgrade. Any changes in the network settings may cause a disruptive upgrade. • Cisco NX-OS Release 5.0(3)N2(2) and Release 5.
Limitations Send documentation c omment s to nexus5kdocs@cisco.com Table 5 Cisco NX-OS Release 5.0(3)N2(1) Supported Upgrades and Downgrades Current Cisco NX-OS Release Upgrade to NX-OS Release 5.0(3)N2(2) or Release 5.0(3)N2(1) Downgrade from NX-OS Release 5.0(3)N2(2) or Release 5.0(3)N2(1) 5.0(3)N1(1c) Nondisruptive upgrade (ISSU) Disruptive downgrade 5.0(2)N2(1) Nondisruptive upgrade (ISSU) Disruptive downgrade 5.0(2)N1(1) Nondisruptive upgrade (ISSU) Disruptive downgrade 4.
Limitations Send documentation c omment s to nexus5kdocs@cisco.com Before downgrading to an earlier release, change the LACP rate to normal. If you ignore the warning and force the installation, then it is possible that the leftover LACP rate fast configuration would still be active with previous releases of software but the behavior would be unpredictable and link flap might occur. We recommend that you change the LACP rate setting to normal. For details, see CSCth93787.
Limitations Send documentation c omment s to nexus5kdocs@cisco.com In a vPC configuration, the MTU per class needs to be consistent on both switches in the vPC domain for the vPC peer link to come up. When upgrading/downgrading a working vPC setup between pre-4.2(1)N1(1) and 4.2(1)N1(1) releases, the MTU is adjusted to make sure that the MCT peer-link always comes up.
Limitations Send documentation c omment s to nexus5kdocs@cisco.com 2008 May 14 15:55:43 switch %KERN-3-SYSTEM_MSG: FCP_ERRFCP_PORT: gat_fcp_isr_ip_fcmac_sync_intr@424, jiffies = 0x7add9a:Unknown intr src_id 41 - kernel These messages are informational only, and result in no loss of functionality.
Limitations Send documentation c omment s to nexus5kdocs@cisco.com SPAN Limitations on Fabric Extender Ports The SPAN limitations on Fabric Extender ports are as follows: • On a Cisco Nexus 5000 Series switch, if the SPAN source is a FEX port then the frames will always be tagged when leaving the SPAN destination. • On a Cisco Nexus 5010 switch or a Nexus 5020 switch, if the SPAN source is an access port on a switch port or FEX port, the spanned frames at the SPAN destination will be tagged.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Checkpoint and Configuration Rollback Limitation When FCoE is enabled, the checkpoint and configuration rollback functionality is disabled. Layer 3 Limitations Asymmetric Configuration In a vPC topology, two Cisco Nexus 5000 switches configured as vPC peer switches need to be configured symmetrically for Layer 3 configurations such as SVIs, Peer Gateway, routing protocol and policies, and RACLs.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Record Number Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats Open Caveat Headline New Open Caveats in NX-OS Release 5.0(3)N2(1) CSCtn00893 The undebug all command does not turn off CDP debugging logs. CSCtn66859 A Cisco Nexus 5548P switch reboots after copying files from the bootlfash to USB flash.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Record Number Open Caveat Headline CSCtl95221 On the Cisco Nexus 5010 switch, an error message is displayed after you issue the wrr cos queue command. CSCtl95401 The FIB does not synchronize with the RIB after the FIB hit the hardware limit and the entries aged out.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Record Number Open Caveat Headline CSCsv95478 On a FEX, the fex pinn redist command does not wait for a user prompt with a y/n. CSCti11823 When upgrading from NX-OS Release 4.2(1)N1(1) to NX-OS Release 4.2(1)N2(1), the 1-Gb HIF LED blinks amber after an ISSU.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Record Number Open Caveat Headline CSCtb58641 Entering the clear mac-address command did not delete a MAC address. CSCtc04213 The VLAN configuration doesn’t get applied on a range of interfaces. CSCtc36397 A vPC role switchover does not occur when the vPC role is a primary operational role.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Record Number Open Caveat Headline CSCth98138 The command output for the show fc-port-security command for some virtual Fibre Channel interfaces is wrong. CSCti51365 During an ISSU, if SAN port channels are down, the down status is not displayed correctly.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Record Number Open Caveat Headline CSCti34155 The output for the show run ipqos all command does not show the default queuing class map. CSCti61513 The match ip rtp command is not supported in the match-all class. Configuration Rollback CSCti77835 A rollback fails to revert to the earlier VLAN configuration.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 6 Record Number Cisco NX-OS Release 5.0(3)N2(1) and Release 5.0(3)N2(2) Open Caveats (continued) Open Caveat Headline CFS CSCsl73766 RADIUS configuration distribution via CFS is unsupported. CSCsm16222 Roles configuration distribution via CFS is unsupported. CSCsr35452 CFS-based distribution of the NTP peer configuration does not work.
Caveats Send documentation c omment s to nexus5kdocs@cisco.com Table 7 Cisco NX-OS 5.0(3)N2(2) Resolved Caveats Record Number Resolved Caveat Headline CSCtr59635 Multihop FCoE: Any \"Storm-control brodcast level\" hanging LUN access CSCtr65682 An SNMP memory leak associated with libcmd() may ocurr. CSCtr76417 A memory leak in a port profile (ppm) process associated with libavl() may occur. CSCts10593 A Nexus 5000 Series kernel panic is caused by a jumbo packet hitting the mgmt0 interface.
Related Documentation Send documentation c omment s to nexus5kdocs@cisco.com Table 8 Cisco NX-OS 5.0(3)N2(1) Resolved Caveats Record Number Resolved Caveat Headline CSCto68011 On Cisco Nexus 5000 Series Switches and Cisco Nexus 2000 Series Fabric Extenders running in FC switching mode, an SNMP get request causes the fcdomain service to fail. CSCto69352 On a Cisco Nexus 5596UP switch, the show tech-support command causes a service failure and the switch reboots.
Related Documentation Send documentation c omment s to nexus5kdocs@cisco.com Cisco Nexus 5000 Series NX-OS Security Configuration Guide Cisco Nexus 5000 Series NX-OS System Management Configuration Guide Cisco Nexus 5000 Series NX-OS Unicast Routing Configuration Guide Cisco Nexus 5000 Series Switch NX-OS Software Configuration Guide Cisco Nexus 5000 Series Fabric Manager Configuration Guide, Release 3.4(1a) Cisco Nexus 7000 Series NX-OS Fundamentals Configuration Guide, Release 4.
Related Documentation Send documentation c omment s to nexus5kdocs@cisco.com Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.
Related Documentation Send documentation c omment s to nexus5kdocs@cisco.com Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, for Cisco NX-OS Release 5.0(3)N2(2) and Release 5.