Cisco NX-OS System Messages Reference (OL-15994-03, July 2009)

Send document comments to nexus7k-feedback-doc@cisco.com
2-724
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SYSTEMHEALTH Messages
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_PROCESS_ERRORS: Compact flash
firmware CRC checksum procedure failed on module [dec]. Reason [dec]
Explanation Compact flash firmware CRC checksum procedure failed.
Recommended Action Try restarting the cf-crc-check using system health clear-errors module <x>
cf-crc-check. If the condition still persists, schedule a downtime and replace the compact flash on
the affected module.
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_TEST_FAILING: Compact flash firmware
CRC checksum validation starting to fail on module [dec].
Explanation Compact flash firmware CRC checksum might be bad on this module.
Recommended Action Schedule a downtime and replace the compact flash on the affected module.
Do not attempt any hitless up/downgrades.
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_RECALLED: Compact Flash on module [dec]
was recalled.
Explanation The Compact flash model has data retention issues and needs to be replaced.
Recommended Action Please schedule a downtime and replace the compact flash on this module.
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_INTERN_ERRORS: Compact Flash
firmware re-flash procedure cannot proceed due to internal errors on module [dec].
Explanation Compact flash firmware re-flash procedure ended up in errors.
Recommended Action Try restarting the test using system health clear-errors module <x> cf-re-flash.
If the condition still persists, schedule a downtime and replace the compact flash on the affected
module.
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_TEST_FAILING: Compact flash
firmware refresh procedure starting to fail on module [dec].
Explanation Compact flash might be dead on this module.
Recommended Action Schedule a downtime and replace the compact flash on the affected module.
Do not attempt any hitless up/downgrades.
Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_UNRESPONSIVE: Recalled Compact Flash on
module [dec] is unresponsive.
Explanation The Compact flash model has data retention issues and needs to be replaced.
Recommended Action Please schedule a downtime and replace the compact flash on this module.