Cisco Nexus 5000 Series Switch CLI Software Configuration Guide (OL-16597-01, July 2009)
--------- -----------------------
Step 7
Verify the next hop and destination for the switch.
Example:
switch# show fspf internal route vsan 1
FSPF Unicast Routes
---------------------------
VSAN Number Dest Domain Route Cost Next hops
-----------------------------------------------
1 0x61(97) 500 fc2/2
1 0x62(98) 1000 fc2/1
fc2/2
1 0x63(99) 500 fc2/1
1 0x65(101) 1000 fc2/4
Step 8
Verify the name server information.
Example:
switch# show fcns data vsan 1
VSAN 1:
------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
------------------------------------------------------------------
0x610400 N 10:00:00:00:c9:24:3d:90 (Emulex) scsi-fcp
0x6105dc NL 21:00:00:20:37:28:31:6d (Seagate) scsi-fcp
0x6105e0 NL 21:00:00:20:37:28:24:7b (Seagate) scsi-fcp
0x6105e1 NL 21:00:00:20:37:28:22:ea (Seagate) scsi-fcp
0x6105e2 NL 21:00:00:20:37:28:2e:65 (Seagate) scsi-fcp
0x6105e4 NL 21:00:00:20:37:28:26:0d (Seagate) scsi-fcp
0x630400 N 10:00:00:00:c9:24:3f:75 (Emulex) scsi-fcp
0x630500 N 50:06:01:60:88:02:90:cb scsi-fcp
0x6514e2 NL 21:00:00:20:37:a7:ca:b7 (Seagate) scsi-fcp
0x6514e4 NL 21:00:00:20:37:a7:c7:e0 (Seagate) scsi-fcp
0x6514e8 NL 21:00:00:20:37:a7:c7:df (Seagate) scsi-fcp
0x651500 N 10:00:00:e0:69:f0:43:9f (JNI)
Total number of entries = 12
The Cisco switch name server shows both local and remote entries, and does not time out the
entries.
Note
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
622 OL-16597-01
Advanced Fibre Channel Features and Concepts
Verifying Interoperating Status