Cisco Nexus 5000 Series Switch CLI Software Configuration Guide (OL-16597-01, July 2009)

CHAPTER 42
Managing FLOGI, Name Server, FDMI, and RSCN
Databases
This chapter contains the following sections:
Managing FLOGI, Name Server, FDMI, and RSCN Databases, page 593
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Information About Fabric Login
In a Fibre Channel fabric, each host or disk requires an FC ID. Use the show flogi command to verify if a
storage device is displayed in the fabric login (FLOGI) table as in the following examples. If the required
device is displayed in the FLOGI table, the fabric login is successful. Examine the FLOGI database on a
switch that is directly connected to the host HBA and connected ports.
The following example shows how to verify the storage devices in the fabric login (FLOGI) table:
switch# show flogi database
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
---------------------------------------------------------------------------
fc2/3 1 0xb200e2 21:00:00:04:cf:27:25:2c 20:00:00:04:cf:27:25:2c
fc2/3 1 0xb200e1 21:00:00:04:cf:4c:18:61 20:00:00:04:cf:4c:18:61
fc2/3 1 0xb200d1 21:00:00:04:cf:4c:18:64 20:00:00:04:cf:4c:18:64
fc2/3 1 0xb200ce 21:00:00:04:cf:4c:16:fb 20:00:00:04:cf:4c:16:fb
fc2/3 1 0xb200cd 21:00:00:04:cf:4c:18:f7 20:00:00:04:cf:4c:18:f7
vfc3/1 2 0xb30100 10:00:00:05:30:00:49:63 20:00:00:05:30:00:49:5e
Total number of flogi = 6.
The following example shows how to verify the storage devices attached to a specific interface:
switch# show flogi database interface vfc1/1
INTERFACE VSAN FCID PORT NAME NODE NAME
---------------------------------------------------------------------------
vfc1/1 1 0x870000 20:00:00:1b:21:06:58:bc 10:00:00:1b:21:06:58:bc
Total number of flogi = 1.
The following example shows how to verify the storage devices associated with VSAN 1:
switch# show flogi database vsan 1
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01 593