Cisco Nexus 5000 Series Switch CLI Software Configuration Guide (OL-16597-01, July 2009)

The one-time distribution of the full zone set is supported in interop 2 and interop 3 modes, and not in
interop 1 mode.
Note
Use the show zone status vsan vsan-id command to check the status of the one-time zone set distribution
request.
switch# show zone status vsan 3
VSAN: 3 default-zone: permit distribute: active only Interop: 100
mode:basic merge-control:allow
session:none
hard-zoning:enabled
Default zone:
qos:none broadcast:disabled ronly:disabled
Full Zoning Database :
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Name: nozoneset Zonesets:1 Zones:2
Status: Zoneset distribution completed at 04:01:06 Aug 28 2004
About Recovering from Link Isolation
When two switches in a fabric are merged using a TE or E port, these TE and E ports may become isolated
when the active zone set databases are different between the two switches or fabrics. When a TE port or an
E port become isolated, you can recover that port from its isolated state using one of three options:
Import the neighboring switch’s active zone set database and replace the current active zone set (see the
figure below).
Export the current database to the neighboring switch.
Manually resolve the conflict by editing the full zone set, activating the corrected zone set, and then
bringing up the link.
Figure 68: Importing and Exporting the Database
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
556 OL-16597-01
Configuring and Managing Zones
About Recovering from Link Isolation