Cisco Nexus 5000 Series Switch CLI Software Configuration Guide (OL-16597-01, July 2009)

Autocreated SAN port channels are indicated explicitly to help differentiate them from the manually created
SAN port channels. The following example shows how to display an autocreated port channel:
switch# show interface fc2/1
fc2/1 is trunking
Hardware is Fibre Channel, FCOT is short wave laser
Port WWN is 20:0a:00:0b:5f:3b:fe:80
...
Receive data field Size is 2112
Beacon is turned off
Port-channel auto creation is enabled
Belongs to port-channel 123
...
Default Settings for SAN Port Channels
The table below lists the default settings for SAN port channels.
Table 72: Default SAN Port Channel Parameters
DefaultParameters
FSPF is enabled by default.Port channels
Administratively up.Create port channel
On.Default port channel mode
Disabled.Autocreation
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01 529
Configuring SAN Port Channels
Default Settings for SAN Port Channels