Cisco Nexus 5000 Series Release Notes for Release 5.0(3)N2(2) (June 2011)

Send documentation comments to nexus5kdocs@cisco.com
8
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, for Cisco NX-OS Release 5.0(3)N2(2) and Release 5.0(3)N2(1)
New and Changed Features
Fibre Channel over Ethernet N-Port Virtualization
Beginning with Cisco NX-OS Release 5.0(3)N2(1), Fibre Channel over Ethernet N-Port Virtualization
(FCoE NPV) is supported on the Cisco Nexus 5000 Series switches. The FCoE NPV feature is an
enhanced form of FIP snooping that provides a secure method to connect FCoE-capable hosts to an
FCoE-capable FCoE forwarder (FCF) switch. The FCoE NPV feature provides the following benefits:
FCoE NPV does not have the management and troubleshooting issues that are inherent to managing
hosts remotely at the FCF.
FCoE NPV implements FIP snooping as an extension to the NPV function while retaining the
traffic-engineering, VSAN-management, administration and trouble-shooting aspects of NPV.
FCoE NPV and NPV together allow communication through FC and FCoE ports at the same time.
This provides a smooth transition when moving from FC to FCoE topologies.
For more information, see the Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide,
Release 5.0(3)N2(1).
Flex Links
Beginning with Cisco NX-OS Release 5.0(3)N2(1), Flex Links are supported on Cisco Nexus 5000
Series switches. Flex Links are a pair of a Layer 2 interfaces (switchports or port channels), where one
interface is configured to act as a backup to the other. Flex Links are typically configured in
service-provider or enterprise networks where customers do not want to run STP. Flex Links provide
link-level redundancy that is an alternative to Spanning Tree Protocol (STP). STP is automatically
disabled on Flex Links interfaces.
Note To configure flex links, you must remove the LAN_ENTERPRISE_SERVICES_PKG,
LAN_BASE_SERVICES_PKG and then reload the switch.
For more information, see the Cisco Nexus 5000 Series NX-OS Layer 2 Switching Configuration Guide,
Release 5.0(3)N2(1).
Configurable Hash Polynomial
Beginning with Cisco NX-OS Release 5.0(3)N2(1), the Cisco Nexus 5500 Platform switches support 8
hash polynomials that can be used for compression on the hash-parameters. Depending on variations in
the hash parameters for egress traffic flows from a port channel, different polynomials could provide
improved load distribution results.
For more information, see the Cisco Nexus 5000 Series NX-OS Layer 2 Switching Configuration Guide,
Release 5.0(3)N2(1).
Orphan Port Shutdown
Beginning with Cisco NX-OS Release 5.0(3)N2(1), you can suspend a non-virtual port channel (vPC)
port when a vPC secondary peer link goes down. A non-vPC port, also known as an orphaned port, is a
port that is not part of a vPC.
For more information, see the Cisco Nexus 5000 Series NX-OS Layer 2 Switching Configuration Guide,
Release 5.0(3)N2(1).