Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, for Cisco NX-OS Release 5.0(2)N1(1) and NX-OS Release 5.0(2)N2(1) OL-22747-02, December 2010)
Send documentation comments to nexus5kdocs@cisco.com
35
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, for Cisco NX-OS Release 5.0(2)N1(1) and NX-OS Release 5.0(2)N2(1)
OL-22747-02
Caveats
Symptom: When a SAN port channel is created, the following syslog message is displayed:
2008 May 20 06:09:13 switch %PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send
MAP_PARAM_FROM_CHANNEL to sap 45: Broken pipe"
There is no functionality loss and this message can be ignored.
Workaround: None.
• CSCso01268
Symptom: The following error message is displayed when a module is hot-swapped out:
2005 Jan 1 00:08:23 switch %KERN-4-SYSTEM_MSG: SI-VDC map entry <0, 0x0> does not
exist! - kernel"
There is no functionality loss and the message can be ignored.
Workaround: None.
• CSCsq57558
Symptom: Enhanced Inter Switch Link (EISL) encapsulation is not supported on a Fibre Channel
SPAN destination port. When EISL encapsulation is configured on the SPAN destination (SD) port,
a VFT header is added to the packets going out of the SD port. The VFT header has VSAN
information that helps distinguish traffic for various VSANs. This applies to any Fibre Channel
SPAN source. By default, EISL encap is not added and packets are sent out without a VFT header,
and independent of the type of SPAN source port. For a Cisco Nexus 5000 Series switch, the
switchport encap EISL command does not have any effect.
Workaround: Use the Ethernet SPAN destination port to SPAN Fibre Channel traffic. FCoE packets
going out of the Ethernet SPAN destination port contain VSAN information in the Ethernet VLAN
tag.
• CSCsq90423
Symptom: EISL encapsulation is not supported on Fibre Channel SPAN destination port in NPV
mode. When EISL encapsulation is configured on the SPAN destination (SD) port, a VFT header is
added to the packets going out of the SD port. The VFT header has VSAN information, which helps
distinguish traffic for various VSANs. This applies to any Fibre Channel SPAN source. By default,
EISL encapsulation is not added and packets are sent out without a VFT header, and independent of
the type of SPAN source port. For a Cisco Nexus 5000 Series switch, the switchport encap EISL
command does not have any effect.
Workaround: Use the Ethernet SPAN destination port to SPAN Fibre Channel traffic. FCoE packet
going out of the Ethernet SPAN destination port contain VSAN information in the Ethernet VLAN
tag.
• CSCsv93922
Symptom:
If the modulo(%) operator is used in a Cisco Nexus 2000 Series Fabric Extender
description the show fex <fex-id> command brings up the following error message
ERROR: bad format: non escaped % not followed by 's'.
Workaround: Remove the modulo(%) operator from the Cisco Nexus 2000 Series Fabric Extender
description
• CSCsv95478
Symptom:The Cisco Nexus 2000 Series Fabric Extender pinning redistribute command does not
wait for user prompt with a yes or no operation.
Workaround: None.
• CSCsv15775