Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3) (OL-29201-02, August 2, 2013)

32
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3)
OL-29201-02
Caveats
The show running-configuration ivr command does not display the changes when a device
alias member in an Inter-VSAN routing zone (IVR zone) is renamed.
The port world wide name (pWWN) associated with the device alias is found dissociated in the
port security database.
Adevice alias member is not found in the port security database.
Condition: This situation occurs when all or one of the conditions is met:
A user attempts to perform a device-alias operation in batch, such as renaming an offline device
alias to an existing online device alias or vice versa.
A device alias was renamed.
A device alias was deleted and an existing device alias is renamed to the deleted device alias in
the same commit.
A device alias, which is not configured, resides in the DPVM database and an online device is
renamed to the former.
The IVR distribute option is enabled and the device alias is in enhanced mode, and the changes
in a device alias is not updated to the IVR running configuration.
Workaround: Add the offline member to the device alias database, revert to the previous name if
you have renamed a device alias, and flap the ports that are connected to the affected zone member.
CSCui16928
Symptom: Although the http-server feature is enabled by default, Element Manager cannot be
downloaded.
Condition: This situations occurs on the Cisco MDS 9710 Director running MDS NX-OS Release
6.2(3) software.
Workaround: You must enable the http-server by using the feature http-server command.
CSCui21601
Symptom The Cisco MDS 9710 Director does not allow a copy running saving configurations and
a switch reload operation.
Condition: Active Fibre Channel Redirect (FC-Redirect) configurations are present in Cisco MDS
9710 Director.
Workaround: Remove the MDS 9710 Director from the fabric.
CSCuf35479
Symptom: The “Bad IPv6 host address” error appears when the snmp-server hostname is configured
instead of the IP address. This issue occurs when the domain name and the name-server IP address
are configured.
Workaround: Configure the IP addresses instead of the host name.
CSCud07594
Symptom: In a virtual SAN (VSAN), the Inter-switch Link (ISL) might fail after entering the
suspend command followed by the no suspend command.
Condition: This situation occurs if the no suspend command is entered after a VSAN suspend
operation.
Workaround: After entering the suspend command, wait 10 to 15 at least 5 minutes and then use
the no suspend command.