Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3) (OL-29201-02, August 2, 2013)
32
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3)
OL-29201-02
Caveats
–
The show running-configuration ivr command does not display the changes when a device
alias member in an Inter-VSAN routing zone (IVR zone) is renamed.
–
The port world wide name (pWWN) associated with the device alias is found dissociated in the
port security database.
–
Adevice alias member is not found in the port security database.
Condition: This situation occurs when all or one of the conditions is met:
–
A user attempts to perform a device-alias operation in batch, such as renaming an offline device
alias to an existing online device alias or vice versa.
–
A device alias was renamed.
–
A device alias was deleted and an existing device alias is renamed to the deleted device alias in
the same commit.
–
A device alias, which is not configured, resides in the DPVM database and an online device is
renamed to the former.
–
The IVR distribute option is enabled and the device alias is in enhanced mode, and the changes
in a device alias is not updated to the IVR running configuration.
Workaround: Add the offline member to the device alias database, revert to the previous name if
you have renamed a device alias, and flap the ports that are connected to the affected zone member.
• CSCui16928
Symptom: Although the http-server feature is enabled by default, Element Manager cannot be
downloaded.
Condition: This situations occurs on the Cisco MDS 9710 Director running MDS NX-OS Release
6.2(3) software.
Workaround: You must enable the http-server by using the feature http-server command.
• CSCui21601
Symptom The Cisco MDS 9710 Director does not allow a copy running saving configurations and
a switch reload operation.
Condition: Active Fibre Channel Redirect (FC-Redirect) configurations are present in Cisco MDS
9710 Director.
Workaround: Remove the MDS 9710 Director from the fabric.
• CSCuf35479
Symptom: The “Bad IPv6 host address” error appears when the snmp-server hostname is configured
instead of the IP address. This issue occurs when the domain name and the name-server IP address
are configured.
Workaround: Configure the IP addresses instead of the host name.
• CSCud07594
Symptom: In a virtual SAN (VSAN), the Inter-switch Link (ISL) might fail after entering the
suspend command followed by the no suspend command.
Condition: This situation occurs if the no suspend command is entered after a VSAN suspend
operation.
Workaround: After entering the suspend command, wait 10 to 15 at least 5 minutes and then use
the no suspend command.