Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3) (OL-29201-02, August 2, 2013)
30
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(3)
OL-29201-02
Caveats
Condition: This issue occurs only in Cisco MDS DS-X9232-256K9 and DS-X9248-256K9
modules. You can see the AAA message only if the AAA command authorization is configured.
Workaround: This issue is resolved.
• CSCtz15893
Symptom: Logs for Cisco MDS Generation 4 Fibre Channel switching module DS-X9232-259K9
and DS-X9248-256K9 are displayed in a format that does not identify the specific interface.
Condition: This situation occurs only for the DS-X9232-259K9 and DS-X9248-256K9 Fibre
Channel switching modules.
Workaround: This issue is resolved.
• CSCug69116
Symptom: Several types of Embedded Event Manager (EEM) events on Cisco MDS Fibre Channel
switching modules fail to be logged on the supervisor.
Condition: This situation occurs only for events that originate from the Cisco MDS
DS-X9232-256K9 and DS-X9248-256K9 switching modules.
Workaround: This issue is resolved.
• CSCuf54635
Symptom: When both the Enterprise Package and the Mainframe Package licenses are installed and
the fabric binding feature is enabled, the standby supervisor module goes into a failure state.
Condition: This situation occurs only when both the MAINFRAME and ENTERPRISE license are
installed.
Workaround: This issue is resolved.
• CSCue15656
Symptom: After performing an SNMP set operation to the CONFIG-COPY-MIB from Cisco
Datacenter Network Manager (DCNM), polling the ccCopyState OID returns successful even if the
operation fails.
Condition: This situation occurs during the config copy operation to a TFTP server.
Workaround: This issue is resolved.
• CSCuf64822
Symptom: The DCBX local information shows LLS DCBX registration when a port is in the shut
state:
Local DCBXP Control information:
Operation version: 00 Max version: 00 Seq no: 1 Ack no: 0
Type/
Subtype Version En/Will/Adv Config
006/001 000 Y/N/Y 80
In this example 006/001 is the LLS TLV.
In general, all the other DCBX features are deregistered on a port down and this symptom is not seen
in the DCBX output. However, the LLS is not deregistered when a port is shut, and therefore it keeps
appearing in the output.
Condition: This situation occurs after a switchover or module reload.
Workaround: This issue is resolved.
• CSCuf50037