HP StorageWorks C-Series iSCSI Configuration Guide (AA-RW7PE-TE, December 2006)

You can use either Fabric Manager or the switch CLI to create and modify SAN zones. As a best practice
of SAN management, HP recommends that you create separate iSCSI zones that contain the iSCSI
WWPNs and the storage WWPNs it will access. Ref er to the Cisco conguration documentation to
create, modify, or activate SAN zones.
NOTE:
HP does not support multi-pathing software installed on non-Windows iSCSI initiators connected to the
C-Series IP Storage Services Modules (IPS-4, IPS-8), Multi-protocol Services Module (14/2), or MDS
9216i switch. iSCSI initiators can be zoned with only a single WWPN from the HP storage controller.
Figure 9 shows an example of an iSCSI initiator, W2KX03 (33.33.33.143), zoned with a single p o rt
from an EV A named HSV04, in a zone named iSCSI-HSV04-ONE-PORT.
When the new zone is activated, the iSCSI Initiator can log in to the storage controller.
Figure 9 C-Series Zone containing iSCSI Initiator w ith single H SV port
Creating an iSCSI host
Conguring iSCSI storage on the EVA controller
During initial setup, the iSCSI Initiator must log in to the storage controller before the EVA can recognize
the iSCSI initiator’s WWPN. You can set the controller port as a Persistent T ar get which will permit the
iSCSI Initiator to reconnect to the storage controller a fter a power cycle or reboot.
CAUTION:
FailuretoenablePersistentTargetduringcontroller login prohibits the iSCSI Initiator from accessi ng
storage automatically after a power cycle or reboot, requiring another login to the storage controller.
Initial iSCSI Initiator EVA login
1. From
the the Microsoft iSCSI Initiator Properties window's Available Targets tab, click Refresh.
C-Series iSCSI 21