Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(1) (OL-29201-01, April 12, 2013)

29
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 6.2(1)
OL-29201-01
Caveats
Resolved Caveats
CSCue55653
Symptom: A Cisco MDS 9000 18/4-Port Multiservice Module (DS-X9304-18K9) might reboot
during an ISSU or ISSD and cause traffic to be interrupted on Fibre Channel ports on that module
and cause the ISSU or ISSD process to stop. The reset reason is “Fatal Module Error” as seen in the
following example:
switch# show logging onboard module 4
. . .
Fri Jan 11 16:55:48 2013: Card Uptime Record
----------------------------------------------
Uptime: 15980, 0 days 4 hour(s) 26 minute(s) 20 second(s)
Reset Reason: Reset Requested due to Fatal Module Error (4)
Card Mode..........................: Runtime
This issue can only occur during an ISSU or ISSD from Cisco NX-OS Release 5.2(x) software. No
other releases are affected.
This issue might occur if both of the following conditions are true:
The compression configuration of an FC IP tunnel changed since the FC IP engine was last
reloaded. This change includes modifying existing or newly created FC IP tunnels.
Table 20 Open Caveats and Resolved Caveats Reference
DDTS Number
NX-OS Software Release (Open
or Resolved)
NX-OS Software Release (Open
or Resolved)
5.2(8) 6.2(1)
Severity 2
CSCue55653 OR
CSCue92054 —R
CSCug01540 —O
CSCug13649 —O
CSCug17272 —O
CSCug22090 —O
CSCug25141 —O
Severity 3
CSCtr50223 OO
CSCty82821 OO
CSCud49969 —R
CSCuf54635 —O
CSCuf64822 —O
CSCug14717 —O
Severity 4
CSCuf35479 —O