HP StorageWorks C-Series iSCSI Configuration Guide (AA-RW7PE-TE, December 2006)
(XConnects) (ports 17 a nd 18) and to ensure all ports are in the same VLAN. For information on the BBI
see the HP ProLiant BL p-Class GbE2 Interconnect Switch Browser-based Interface Reference Guide.
Disabling the cross connection ports
With XConnects
between Interconnect A and Interconnect B, the multi-path solution may use loops
established at the interconnect switching level. To avoid this disable the XConnects. Each interconnect
model has different XConnect ports. Some interconnects don’t enable these ports by default. The
following procedure uses the GbE2. See the interconnect documentation for more information.
1. Log in to the first interconnect through the BBI.
2. Click t he CON
FIGURE tab on the BBI main window (Figure 43).
Figure 43 BBI main window
3. Click the folder icon next to p-Class GbE2 Switch.
4. Navigate to the Switch Ports icon in the Switch folder (Figure 44).
Figure 44 Switc h Ports ico n location
5. Disable Sw itch Port State for ports 17 and 18 (Figure 45).