Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-88
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message FCDOMAIN-6-NON_VIRTUAL_DOMS_CONFLICTS: During VSAN merge detected
conflict between two switches having the same non-virtual domain ID [dec] and the
same WWN [chars].
Explanation
It has been detected that two switches have the same non-virtual domain ID [dec] and
the same WWN [chars].
Recommended Action Check which switches have the same WWN and change either one; then
change the domain ID of either one.
Introduced Cisco MDS SAN-OS Release 2.0(1b).
Deprecated Cisco MDS SAN-OS Release 3.0(1).
Error Message FCDOMAIN-6-NOTOWNER: Feature [dec] cannot free FCID
([dec]:[dec]:[dec]).
Explanation
Feature universal unique ID (UUID) cannot free the FC ID shown in the error message
because it is not its owner.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message FCDOMAIN-6-OTHER_SIDE_VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN merge
detected overlap with virtual IVR domain ID [dec] from across the link.
Explanation
The VSAN merge detected an overlap between the local VSAN domain ID list and the
IVR virtual domain ID list in the remote VSAN.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message FCDOMAIN-6-PSWSSTARTED: Principal Switch Selection started.
Explanation
A principal switch selection (PSwS phase) has started.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.3(4a).
Error Message FCDOMAIN-6-RCF_STARTED: RCF started by [chars].
Explanation
A fabric reconfiguration has started in this VSAN.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.1(2).