Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.1(3a) (OL-17675-05 E0, March 2009)

Send documentation comments to mdsfeedback-doc.com.
43
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.1(3a)
OL-17675-05
Limitations and Restrictions
> no destination-profile testProfile transport-method email
> destination-profile testProfile transport-method http
> destination-profile testProfile http https://xyz.abc.com
> destination-profile testProfile alert-group all
> transport email smtp-server 64.104.140.134 port 25 use-vrf management
> transport email from abc@cisco.com <mailto:abc@cisco.com>
> enable
> commit
When you attempt to apply these commands in the ASCII configuration, the following commands fail:
> no destination-profile testProfile transport-method email
> destination-profile testProfile transport-method http
> destination-profile testProfile http https://xyz.abc.com
To work around this issue, issue these commands after the commit command.
Availability of F Port Trunking and F Port Channels
Trunking F ports and trunking F port channels are not supported on the following MDS 9000
components:
DS-C9134-K9, Cisco MDS 9134 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
DS-C9124-K9, Cisco MDS 9124 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
Trunking F ports, trunking F port channels and regular F port channels are not supported on the following
MDS 9000 components:
DS-C9216i-K9, Cisco MDS 9216i Multilayer Fabric Switch
DS-X9016, Cisco MDS 9000 2-Gbps16-Port Fibre Channel Switching Module
DS-X9032, Cisco MDS 9000 2-Gbps 32-Port Fibre Channel Switching Module
DS-X9032-14K9, Cisco MDS 9000 14/2-Port Multiprotocol Services Module (MPS-14/2)
For configuration information, refer to the “Configuring Trunking” section in the Cisco MDS 9000
Family CLI Configuration Guide.
Reserved VSAN Range and Isolated VSAN Range Guidelines
On an NPV switch with a trunking configuration on any interface, or on a regular switch where the
feature fport_channel_trunk command has been issued to enable the F PortChannel feature, follow
these configuration guidelines for reserved VSANs and the isolated VSAN: