HP StorageWorks C-series Fabric Switches for NX-OS 5.0(4b) Release Notes (AA-RWQBD-TE, March 2011)

19 MDS 9000 Series Multilayer Director & Multilayer Fabric Switches Release Notes
3. Enter the following to enter configuration mode:
switch# config terminal
4. Enter the following command to enter the VSAN database:
switch(config)# vsan database
5. Enter the following command to enable the VSAN(s) that contain the Continuous Access
EVA and/or DRM fabric to src-dst-id loadbalancing:
switch(config-vsan-db)# vsan <1-4094> loadbalancing src-dst-id
switch(config-vsan-db)# exit
switch(config)# exit
6. Verify that src-dst-id is enabled for the desired VSAN by entering the following
command:
switch# show vsan <1-4094>
In the following example, VSAN 1 loadbalancing is set to src-id/dst-id
switch# show vsan 1
vsan 1 information
name: vsan1 state: active
interoperability mode: default
loadbalancing: src-id/dst-id
operational state: up
7. Type the following to copy the running configuration into the startup configuration:
switch# copy running-config startup-config
Refer to the Cisco MDS 9000 Family Fabric Manager Switch Configuration Guide to set
src-dst-id using Device/Fabric Manager.
Note: The running configuration overwrites the startup configuration.
HP STORAGEWORKS SN6000C FABRIC SWITCH
The HP StorageWorks SN6000C Fabric Switches (MDS 9148) have fixed configurations with 16
and 32 full rate 8-Gbps fibre channel ports. The switch can be upgraded up to 48-ports in 8 port
increments with an on demand port activation license.
CISCO MDS 8Gb FABRIC SWITCH FOR HP
BLADESYSTEM c-CLASS
The Cisco MDS 8Gb 12-port fabric switch and the MDS Cisco 8Gb 24-port fabric switch for HP
BladeSystem c-Class have fixed configurations with 8-internal/4-external or 16-internal/8-
external full rate 8-Gbps fibre channel ports. The 12-port switch can be upgraded to the 24-port
switch with an on demand port activation license.