Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1) (OL-16601-01 G0)
Send documentation comments to nx5000-docfeedback@cisco.com
15
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1)
OL-16601-01
Caveats
Workaround: Use the CLI to set the mgmt0 IP address.
• CSCsm16222
Symptom: CFS does not support roles configuration distribution. Enter the show cfs application
command to see the registered applications.
Workaround: Any features not registered with CFS need to be configured locally on the switch.
• CSCsl73766
Symptom: CFS does not support RADIUS configuration distribution. Enter the show cfs
application command to see the registered applications.
Workaround: Any features not registered with CFS need to be configured locally on the switch.
• CSCso25966
Symptom: When an LACP port channel is configured between Catalyst 6500 and Nexus 5000 Series
switches, and the configurations on both sides of the port channel do not match, the Catalyst 6500
LACP ports may change to the errordisable state.
Workaround: Fix the configuration to make it consistent on both peer switches of the port channel,
and perform a shut and no shut operation on the Catalyst 6500 port channel interface.
• CSCso27446
Symptom: When a shutdown command is issued to the mgmt0 interface on a Nexus 5000 Series
switch, the link never goes down and the remote end does not indicate that the link is down.
Workaround: None.
• CSCso46345
Symptom: The current version of NX-OS software running on the Nexus 5000 Series switches does
not support Brocade i10K interop mode 4. The i10k v9.2.0.8 is supported by MDS in SAN-OS
3.2(2c), and 3.2(3) with interop mode 1 and 4.
Workaround: None.
• CSCso65934
Symptom: Virtual interfaces are created by specifying the interface name in configuration mode. If
the interface does not exist, the system creates the interface, and then enters interface configuration
mode. If the user role prohibits access to that interface, this CLI is rejected and the user does not
enter interface configuration mode, although the interface is created. Similarly, if a user does not
have access to a virtual interface, the interface can still be deleted with the no interface command.
Workaround: None.
• CSCso74872
Symptom: When two SNMP walks are started simultaneously, one of them may fail with the
following error:
OID not increasing
This problem does not occur with a single SNMP walk.
Workaround: This is not a permanent failure. Restart the walk and the problem will not occur as
long as there is no other SNMP walk in progress.
• CSCso82992
Symptom: Delete and insert role scopes for a role may fail and display the following error:
entry already exists