Cisco Nexus 5000 Series Command Reference Release 4.0(1a)N2(1) (OL-16599-01, March 2009)

Send comments to nx5000-docfeedback@cisco.com
9-27
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 9 Fibre Channel Show Commands
show fctimer
show fctimer
To view the Fibre Channel timers (fctimer), use the show fctimer command.
show fctimer [d_s_tov [vsan vsan-id] | e_d_tov [vsan vsan-id] | f_s_tov [vsan vsan-id] | r_a_tov
[vsan vsan-id] | last action status | pending | pending-diff | session status | status | vsan
vsan-id]
Syntax Description
Command Default None
Command Modes EXEC mode.
Command History
Examples The following example displays configured global TOVs:
switch# show fctimer
The following example displays configured TOVs for a specified VSAN:
switch# show fctimer vsan 10
Related Commands
vsan vsan-id (Optional) Displays information for a VSAN. The range is 1 to 4093.
d_s_tov (Optional) Displays the distributed services time out value (D_S_TOV) in
milliseconds.
e_d_tov (Optional) Displays the error detection time out value (E_D_TOV) in
milliseconds.
f_s_tov (Optional) Displays the fabric stability time out value (F_S_TOV) in
milliseconds.
r_a_tov (Optional) Displays the resource allocation time out value (R_A_TOV) in
milliseconds.
last action status (Optional) Displays the status of the last CFS commit or discard operation.
pending (Optional) Displays the status of pending fctimer commands.
pending-diff (Optional) Displays the difference between pending database and running
config.
session status (Optional) Displays the state of fctimer CFS session.
status (Optional) Displays the Fibre Channel timer status.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
fctimer Configures fctimer parameters.