Cisco Nexus 5000 Series Command Reference Release 4.0(1a)N2(1) (OL-16599-01, March 2009)

Send comments to nx5000-docfeedback@cisco.com
4-8
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 4 Fabric Extender Commands
logging fex
logging fex
To set the logging alert level for Fabric Extender events, use the logging fex command. To reset the
logging level, use the no form of this command.
logging fex [severity-level]
no logging fex [severity-level]
Syntax Description
Command Default None
Command Modes Configuration mode
Command History
Examples This example shows how to set the logging alert level for Fabric Extender events:
switch(config)# logging fex 4
This example shows how to reset the logging level:
switch(config)# no logging fex
Related Commands
severity-level (Optional) Number of the desired severity level at which messages should be logged.
Messages at or numerically lower than the specified level are logged. Severity levels
are as follows:
0—emergency: System unusable
1—alert: Immediate action needed
2—critical: Critical condition—default level
3—error: Error condition
4—warning: Warning condition
5—notification: Normal but significant condition
6—informational: Informational message only
7—debugging: Appears during debugging only
Release Modification
4.0(1a)N2(1) This command was introduced.
Command Description
show fex Displays all configured Fabric Extender chassis connected to the switch.