Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(1c) (OL-14116-08, July 2008)

Send documentation comments to mdsfeedback-doc@cisco.com
37
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(1c)
OL-14116-08
Caveats
If an upgrade is attempted when such active configuration is present, the switch will go into a
disruptive upgrade.
Workaround: None. On the MDS 9222i module, an upgrade from SAN-OS Release 3.2(x) to
Release 3.3(1a) is not supported if there is a Cisco SME or Cisco DMM configuration in the fabric
for hosts and targets attached to the MDS 9222i module.
CSCso41087
Symptom: If FCIP is enabled and the SAN-OS is upgraded, the SNMP service will run into
exception and the following syslog message is displayed:
SNMP Operation(165) failed (62)
setting error index
.
Workaround: Disable FCIP during the SAN-OS upgrade.
CSCsq29607
Symptom: After logging back into Fabric Manager Client, clicking on the Summary tab causes a
disconnect.
Workaround: Exit from Fabric Manager Client then restart Fabric Manager Client and log in again.
CSCsq44360
Symptom: When the startup rising alarm is triggered, the sample value is smaller than the
risingthreshold. This should not trigger an alarm.
Workaround: None.
CSCsq78868
Symptom: Flow statistics on a Generation 2 module may not be accurate if any of the flows that
participate in flow statistics on the module have multiple FSPF paths.
Workaround: For all flows that have flow statistics configured on that module, make sure there is
only one available FSPF path. Use port-channel instead of multiple links to achieve more bandwidth.
CSCin95789
Symptom: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces
on a Windows platform, the configuration web page might not show that the interface has been
selected for traffic capture even though traffic capture on that interface is enabled.
Workaround: Check the logs to clarify that the correct interface has been selected.
CSCse31881
Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might
experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.
Workaround: Before downgrading, remove the IPFC interface on the module and then recreate the
IPFC interface after the downgrade is complete.
CSCse47687
Symptom: If IP ACLs are applied to any IP Storage Gigabit Ethernet port, implicit deny does not
take effect.