Release Notes for Cisco Catalyst Blade Switch 3120 for HP, Cisco IOS Release 12.2(50)SE and Later

25
Release Notes for Cisco Catalyst Blade Switch 3120 for HP, Cisco IOS Release 12.2(50)SE and Later
OL-18270-03
Resolved Caveats
CSCsz05975
A stack member no longer fails when the hostname is longer than 36 characters.
CSCsz12381
When open1x authentication and MAC authentication bypass are enabled on a port, an IP phone is
connected to the port, and DHCP snooping is enabled on the switch, DHCP traffic is now forwarded
on the voice VLAN before open 1x authentication times out and the switch uses MAC authentication
bypass to authorize the port.
CSCsz13490
The switch no longer reloads when you enter several key strokes while in interface-range
configuration mode.
CSCsz14369
If MAC authenication bypass is enabled and the RADIUS server is not available, the switch now
tries to re-authenticate a port after a server becomes available.
CSCsz68923
A TwinGig Converter module in slot 2 is now correctly recognized by the switch software.
CSCsz77920
If you are configuring Flexible Authentication Ordering with web authentication on a switch port
and the switch uses 802.1x to authenticate the the host, Address Resolution Protocol (ARP) now
works properly.
CSCsz79293
When VPN routing and forwarding (VRF) is configured on the stack master, communication no
longer fails after the stack master has shut down.
CSCsz81762
If you enable automatic server testing through the radius-server host ip-address [test username
name] global configuration command, the switch no longer sends requests to the RADIUS server if
the server is not available.
CSCsz89393
SNMP queries to the Bridge-MIB now operate on switch stacks with five or more stack members
and a large number of active ports.
Cisco IOS Caveats Resolved in Cisco IOS Release 12.2(50)SE1
CSCsb46724
If the connection to a primary AAA server fails, the backup server is now queried for login access.
CSCsr92741
When a TCP packet with all flags set to zero (at the TCP level) is sent to a remote router, the remote
(destination) router no longer returns an ACK/RST packet back to the source of the TCP segment.
CSCsy24510
The switch now accepts an encrypted secret password.
CSCsy41470
The switch no longer runs out of memory when an smnpwalk, snmpget, or snmpbulkwalk is run on
the CISCO-ENERGYWISE-MIB.