Release Notes for Cisco Catalyst Blade Switch 3120 for HP, Cisco IOS Release 12.2(50)SE and Later
20
Release Notes for Cisco Catalyst Blade Switch 3120 for HP, Cisco IOS Release 12.2(50)SE and Later
OL-18270-03
Open Caveats
Open Caveats
• CSCsg67684
When a cross-stack LACP EtherChannel has a maximum configuration, such as eight active and
eight hot-standby ports, and there are multiple rapid sequential master failovers and stack rejoins
that cause extreme stress, the port channel might not function as expected. Some ports might not join
the EtherChannel, and traffic might be lost. You can detect the condition by using the remote
command all show etherchannel summary privileged EXEC command.
There is no workaround. The out-of-sync switches must be reloaded.
• CSCsi06399
When a RIP network and IP address are configured on an interface, a traceback error occurs after
you enter the shutdown, no shutdown, switchport, and no switchport interface configuration
commands.
The workaround is to configure the RIP network and the IP address after you configure the interface.
• CSCsi14303
When booting a switch stack configured for IP source guard with port security and dynamic ARP
inspection, a message similar to this might appear:
SYS-2-LINKED: Bad enqueue of 2A3DE74 in queue 22881BC (l3a3-9) -Process=
"Port-Security", ipl= 6, pid= 161 (l3a3-9) -Traceback= 119CC50 11D2264 9571E0 119B4E0
95D41C 80DBD8 80E734 80B998 80AAD4 80B55C 9EB158 9E2544 (l3a3-9)
There is no workaround. This message is only information; switch functionality is not affected.
• CSCsi26444
The error message
%DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND might appear for a switch stack under
these conditions:
–
IEEE 802.1 is enabled.
–
A supplicant is authenticated on at least one port.
–
A new member joins a switch stack.
You can use one of these workarounds:
–
Enter the shutdown and the no shutdown interface configuration commands to reset the port.
–
Remove and reconfigure the VLAN.
• CSCsi52914
When you are configuring a SPAN session, this message might erroneously appear even when two
source sessions are not configured:
% Platform can support a maximum of 2 source sessions
The workaround is to reboot the switch stack.
• CSCsi65551
In certain situations during master switch failover, a VLAN that has been error disabled on a port
might be re-enabled after the master switch failover, even though the port has not been configured
for automatic recovery.
There is no workaround.