Cisco Catalyst Blade Switch 3120 for HP System Message Guide

2-67
Cisco Catalyst Blade Switch 3120 for HP System Message Guide
OL-12249-01
Chapter 2 Message and Recovery Procedures
PM Messages
Error Message PM-4-INT_VLAN_NOTAVAIL: Failed to allocate internal VLAN in Port
Manager.
Explanation
The port manager failed to find any available internal VLAN.
Recommended Action Delete some extended-range VLANs created by users, or remove some features
(such as routed ports) that require internal VLAN allocation. To delete extended-range VLANs, use
the no vlan vlan-id global configuration command. To delete a routed port, use the no switchport
interface configuration command.
Error Message PM-4-INVALID_HOST_ACCESS_ENTRY: Invalid Host access entry type ([dec])
is received.
Explanation
An invalid host access entry type was received; the host access entry should be a
configured or a dynamic type. [dec] is the entry type that is received.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact HP
technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting HP, see the “Error Message Traceback
Reports” section on page 1-5.
Error Message PM-4-LIMITS: The number of vlan-port instances on [chars] exceeded the
recommended limit of [dec].
Explanation
The total number of individual VLAN ports, counted over the module or switch, has
exceeded the recommended limit. VLANs can be counted more than once; if VLAN 1 is carried on
ten interfaces, it will count as ten VLAN ports. On some platforms bundling is also ignored for
purposes of this count; if eight interfaces on the same module are in one bundle, and the port channel
is carrying VLAN 1, it will count as eight VLAN ports. [chars] is the module name (for example,
switch or the module number), and [dec] is the recommended limit.
Recommended Action Reduce the number of trunks and VLANs configured in the module or switch
as recommended in [dec]. Enter the show interfaces trunk privileged EXEC command to see the
total number of trunks and VLANs.
Error Message PM-4-NO_SUBBLOCK: No PM subblock found for [chars].
Explanation
The port manager failed to find the subblock for this interface. [chars] is the interface
name.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact HP
technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting HP, see the “Error Message Traceback
Reports” section on page 1-5.