Cisco Catalyst Blade Switch 3120 for HP System Message Guide

2-54
Cisco Catalyst Blade Switch 3120 for HP System Message Guide
OL-12249-01
Chapter 2 Message and Recovery Procedures
PLATFORM_PM Messages
Error Message PLATFORM_PBR-4-SDM_MISMATCH: [chars] requires sdm template routing.
Explanation
The routing template is not enabled. [chars] is the text string PBR.
Recommended Action Modify the SDM template to enable the routing template. Use the sdm prefer
routing configuration command, and then reload the switch by using the reload privileged EXEC
command.
PLATFORM_PM Messages
This section contains platform port manager (PM) messages.
Error Message PLATFORM_PM-3-IFCOUNTERROR: Unit number [dec] of interface [chars] is
more than max allowed value of [dec].
Explanation
There are too many interfaces configured for the interface type. [dec] is the interface
count, [chars] is the interface, and [dec] is the maximum number of interfaces.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the “Error Message Traceback Reports” section on page 1-5.
Error Message PLATFORM_PM-3-INTVLANINUSE: internal vlan-id [dec] allocated for
interface [chars] is still in use.
Explanation
An internal VLAN ID allocated for an interface is still in use. [dec] is the VLAN ID,
and [chars] is the interface.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the “Error Message Traceback Reports” section on page 1-5.
Error Message PLATFORM_PM-3-NOINTVLAN: internal vlan of interface [chars] is not
active for vlan-id [dec].
Explanation
Internal vlan_data is not active for the given VLAN ID. [chars] is the interface, and
[dec] is the VLAN ID.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the “Error Message Traceback Reports” section on page 1-5.